Accepterar du cookies?Accepterer du brug af cookies ?Do you accept cookies ?
ICI ångpannorICI dampkedlerICI steam boilers
Modell GXModel GXGX series
UtrustningUdrustningAccessories
Standard utrustningStandard udrustningStandard accessories
GX panna uppbyggnad och standardutrustning (även visat vissa tillvalsutrustning)GX kedlens opbygning og standard udrustning (noget tilvalgs udstyr også vist)The GX boiler with standard acessories (some optional accessories also shown)
Dubbel front luckaDobbelt kedel fordørDouble boiler front door
2:a stråk rökkanaler2. træk røgkanaler2nd pass flue gas tubes
3:e stråk rökkanaler3. træk røgkanaler3rd pass flue gas tubes
Extern cylinder för nivågivareEkstern følerbrøndExternal sensor barrel
Matarvatten enhetFødevands systemFeed water unit
Vattenstånds siktglasVandstandsglasLevel gauges
Vågformig eldkammere (endast större pannstorlekar)Bølgeformet brændkammer (kun større kedelstørrelser)Corrugated combustion chamber (only larger boiler sizes)
StyrskåpKontrolskabControl panel
BärramBærerammeSupport frame
BrännarplattaBrænderpladeBurner plate
BrännareBrænderBurner
ICI GX ång pannor levereras fullt utrustad och klar för installation.
Följande standard utrustning levereras med pannan:
1 st automatisk nivå kontroll
1 st drifts pressostat
1 st två-stegs pressostat
1 st P.E.D. godkänt säkerhets pressostat (MAX pressostat) med manuell nollställnings funktion
1 st manometer
2 st säkerhets sensor för låg nivå (katastrofskydd)
1 st ång stopps ventil
2 st P.E.D. godkända säkerhets ventiler
1 st styrpanel 3 fas + N 400V~ 50 Hz
3 st avstängnings ventiler
2 st matar vatten pumpar
1 st botten avblåsnings ventil och stop ventil
3 st backventiler
2 st silar
2 st vattenståndsglas
Isolering med aluminium beklädnad
Frontlucka med isolering
Packning för transport
Dokumentation på skandinaviska
ICI GX damp kedler leveres fuldt udstyrede og klar for installation.
Følgende standard udrustning leveres med kedlen:
1 automatisk niveau kontrol
1 driftspressostat
1 pressostat for to-trins drift
1 P.E.D. godkendt sikkerheds pressostat med manuel nulstillings funktion
1 manometer
2 lavt niveau sikkerheds følere
1 damp hovedstopventil
2 P.E.D. godkendte sikkerheds ventiler
1 kontrolpanel 3 faser + N 400V~ 50 Hz
3 afspærrings ventiler
2 fødevands pumper
1 bundafblæsnings ventil med afspærringsventil
3 kontraventiler
2 snavs samlere
2 niveau indikatorer
Isolering med aluminium beklædning
Forplade med brænder udmuring
Emballering for transport
Dokumentation på Skandinavisk
ICI GX steam boilers are supplied fully equipped and ready for installation.
The boiler is supplied with the following standard equipment:
Steam accessories
1 main steam stop valve (G)
2 spring safety valves, certified to PED 97/23/EC
Instrumentation pipe (F)
Instrumentation pipe with blow-down valve
1 large-dial manometer with check bridle and 3-way test valve (D)
1 limit pressure switch
1 safety pressure switch with manual reset, certified to PED 97/23/EC
Feed water unit (N)
Fitted to a side steel frame and connected to the boiler in suitably sized steel pipework
2 vertical multistage centrifugal pumps suitable for max. 120 °C water temperature
3 isolation valves
2 strainers fitted on pumps suction
3 non-return valves
Purging unit
1 isolation valve
1 quick action blowdown stop valve with manual lever
Level control
2 forged steel level indicators with direct reading reflection box, complete with isolating and blow-down valves (O)
2 level control conductivity probes fitted in boiler shell and connected to control relay for automatic pump start and stop (E)
2 low level conductivity probes fitted in the boiler shell and connected to two distinct control relays for burner lockout at low water level (E, M)
Main control panel (R)
Fitted on side of boiler (option for free standing type)
Isolation class: IP 55
Power supply 3Ph+N / 400v / 50Hz
Mains breaker switch
Feed water pumps breaker switch (off – aut. – on)
Feed water pump selector switch (pump 1 – pump 2)
Burner switch
Level regulation relay (pump control)
1st low level safety relay
2nd low level safety relay
High pressure reset switch with visual alarms lamp
1st low level reset switch with visual alarms lamp
2nd low level reset switch with visual alarms lamp
Alarm siren
Boiler body
Burner plate (T)
Insulation with aluminium cladding
Service deck on top of boiler
Other
Packing for transportation
Documentation
Extra utrustningTilvalgs udstyrOptional accessories
GX panna kan levereras med ett omfattande program avGX kedlerne kan leveres med et omfattende program afA comprehensive selection oftilvals utrustningekstra udrustningoptional extras..is available for the GX boilers.